800.229.4376
614.771.0213
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
|
|
Incremental Linear Encoders
|
|||||||||||||||||||||||||||||||||||||||||||||||||||
Signal Output |
Model |
Description |
|---|
| |
Provides a differential quadrature output at RS422 TTL levels.The periodic reference mark is synchronized with the
A & B signals. Accuracy/Meter = ±0.0004" (±10µm). Resolutions = 10µm, 5µm, 2µm, 1µm or 0.5µm. |
|
| MHG-TT | Provides a differential quadrature output at RS422 TTL levels. The periodic reference mark is synchronized with the A & B signals. Accuracy/Meter = ±0.0002" (±5µm). Resolutions = 10µm, 5µm, 2µm, 1µm, 0.5µm or 0.2µm. |
|
| SPB-TT | Designed specifiaclly for Press Brakes. Provides a differential quadrature output at RS422 TTL levels. The periodic reference mark is synchronized with the A & B signals. Accuracy/Meter = ±0.0004" (±10µm). Resolutions = 10µm, 5µm, 2µm, 1µm or 0.5µm. | |
The MCG linear encoder provides an ultra-low profile for restricted spaces. Provides a differential quadrature output at RS422 TTL levels. The periodic reference mark is synchronized with the A & B signals. Accuracy/Meter = ±0.0002" (±5µm).
Resolutions = 10µm, 5µm, 2µm, 1µm, 0.5µm or 0.2µm. |
||
| TTL Differential AB Quad - No Reference | DSG-TT | For non-servo applications. Provides a differential quadrature output at RS422 TTL levels. No reference marker. Accuracy/Meter
= ±0.0004" (±10µm). Resolutions = 10µm or 5µm |
| DMG-TT | For non-servo applications. Provides a differential quadrature output at RS422 TTL levels. No reference marker. Accuracy/Meter = ±0.0002" (±5µm). Resolutions = 10µm, 5µm, 2µm, or 1µm |
|
| |
SHG-TS | This encoder has a series of six selectable reference markers spaced every 25.4mm. Accuracy/Meter = ±0.0004" (±10µm). Resolutions = 10µm, 5µm, 2µm, 1µm or 0.5µm. |
Designed specifiaclly for Press Brakes. This encoder has a series of six selectable reference markers spaced every 25.4mm. Accuracy/Meter = ±0.0004" (±10µm). Resolutions = 10µm, 5µm, 2µm, 1µm or 0.5µm. |
||
Accuracy/Meter
= ±0.0004" (±10µm). Resolutions (from
the SCC-100) = 20µm signal period. |
||
Accuracy/Meter
= ±0.0002" (±5µm). Resolutions (from
the SCC-100) = 20µm signal period. |
||
Accuracy/Meter
= ±0.0004" (±10µm). Resolutions (from
the SCC-200) = 20µm signal period. |
||
Accuracy/Meter
= ±0.0004" (±10µm). Resolutions (from
the SCC-100) = 20µm signal period. |
||
| MHG-VP | Accuracy/Meter = ±0.0002" (±5µm). Resolutions (from the SCC-200) = 20µm signal period. | |
| MHG-VV | Accuracy/Meter = ±0.0002" (±5µm). Resolutions (from the SCC-100) = 20µm signal period. | |
~1vPP
Sine/Cosine - Single Point |
SHG-VS | Has a series of eight selectable reference markers spaced every 25.4mm. |
Quick and Easy Installation
The design of these linear encoders allow installment
in almost any position, unlike glass-scale linear encoders, which usually
need to be installed with the lip seal facing downwards to prevent contamination.
Self-aligning fixing brackets allow virtually effortless scale mounting,
needing only a single hole for each set of brackets.