800.229.4376
614.771.0213
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
|
SCC-200 Converter
|
||||||||||||||||||||||||||||||||||
Specifications |
|---|
Output Signal |
Serial data from MHG-VP, SHG-VP or
SHG-VS |
|---|---|
Output Signal (sinusoidal voltage) |
~1Vpp differential |
Amplitude Ratio (A to
B) |
0.95 to 1.05 |
Phase Angle |
90° ±5° elec |
Output Resolution |
20µm signal period |
Reference Mark Signal |
Periodic (MHG-VP, SHG-VP); Single
(SHG-VS) |
Reference Mark Zero Crossover Point |
±90° ±5° elec |
Reference Mark Signal
Levels |
0.8 to 1.2Vpp (typically 1Vpp)* |
Power Requirements |
5VDC ±5%, <300mA (with
encoder) |
Overall Dimensions |
131mm x 67mm x 24mm |
There are two (2) different versions
of the SCC-200 converter.
Part #600-82870 is intended for use with MHG-VP series encoders.
Part #600-82875 is intended for use with SHG-VP or SHG-VS series encoders.
Note: The SCC-200 can
be DIN rail mounted.
(European DIN rail standards: EN50022 & EN50035)