Defining Accuracy, Resolution & Repeatability ACCURACY IS NOT a simple subject. It's not enough to say that a particular scale is "extremely accurate" or "mor...

Preferred Industries was purchased by T3 Energy Systems in late 2002. T3 has approximately 25 locations in North America. The Houma, LA location employs approximately 110 people; they bui...
SHG-TS Linear Encoder
The SHG-TS linear encoder is compatible with the majority of PLC and CNC controls. It has a series of four selectable reference markers spaced every 25.4mm. The reference mark selected to be active is dependent on the rotational alignment of the scale relative to the reader head upon installation.
Click here to learn more about Newall's Inductive Encoder Technology
Download SHG-TS Linear Encoder Documents: Encoder Compatilibilty List by Manufacturer (pdf)Dimensional Drawing (<100" travel) (pdf)
Dimensional Drawing (≥100" travel) (pdf)
Installation Manual (pdf)
Newall Linear Encoder Catalog (Newall Linear Encoder Catalog)
Specifications
|
---|
Output Signal
|
TTL Differential A Quad B
|
---|---|
Accuracy/Meter
|
±0.0004" (±10µm)
|
Resolutions
|
10µm, 5µm, 2µm, 1µm or 0.5µm
|
Scale Travels
|
2" to 462" (51mm to 11.73m)
|
Scale Diameter
|
0.601" (15.25mm)
|
Reader Head Dimensions
|
2.05"H x 5.16"L x 1.10"D (52mm x 131mm x 28mm)
|
Reference Marker
|
Single (select 1 of 4)
|
Equivalent Line Count/Inch
|
635, 1270, 3175, 6350, 12,700
|
Maximum Traverse Rate
|
65.6' (20m)/second (10µm), pro-rated to resolution
|
Power Supply
|
5VDC ±5%, <80mA
|
Shock (11ms)
|
100g (IEC 69-2-6)
|
Vibration (55-2000Hz)
|
30g (IEC 68-2-27)
|
Sample Period
|
100µs
|
Environmental Rating
|
IP67, fully submersible (IEC 529) - Exceeds NEMA 6
|
Operating Temperature
|
32° to 131°F (0° to 55°C)
|
Coefficient of Expansion
|
12 x 10-6K
|
Scale Material
|
316 stainless steel
|
Overall Scale Length
|
Scale travel length + 10.2" (258mm)
|
Standard Cable
|
9 core, 11.5' (3.5m) armored
|
Maximum Cable Length
|
72.2' (22m)
|
Standard Connector
|
9 pin "D" type
|
EMC Compliance
|
BS EN 50081-2 and BS EN 61000-6-2
|
Options
|
---|
Resolutions
|
Custom resolutions available
|
---|---|
Non-Armored Cable
|
PUR (polyurethane)
|
Connectors
|
• Honda PCR-E20FS (Fanuc)
• IP67 (NEMA 6) • None (flying lead) |
Cable Lengths
|
22' (7m) or 19.68" (0.5m)
|
Quick and Easy Installation
The design of these linear encoders allow installment in almost any position, unlike glass-scale linear encoders, which usually need to be installed with the lip seal facing downwards to prevent contamination. Self-aligning fixing brackets allow virtually effortless scale mounting, needing only a single hole for each set of brackets.